A lot of my friends from IT industry in order to pass HP certification HP0-P19 exam have spend a lot of time and effort, but they did not choose training courses or online training, so passing the exam is so difficult for them and generally, the disposable passing rate is very low. Fortunately, IT-Tests.com can provide you the most reliable training tool for you. IT-Tests.com provide training resource that include simulation test software, simulation test, practice questions and answers about HP certification HP0-P19 exam. We can provide the best and latest practice questions and answers of HP certification HP0-P19 exam to meet your need.
IT-Tests.com HP HP0-P19 exam training materials can help you to come true your dreams. Because it contains all the questions of HP HP0-P19 examination. With IT-Tests.com, you could throw yourself into the exam preparation completely. With high quality training materials by IT-Tests.com provided, you will certainly pass the exam. IT-Tests.com can give you a brighter future.
IT-Tests.com is a website to improve the pass rate of HP certification HP0-P19 exam. Senior IT experts in the IT-Tests.com constantly developed a variety of successful programs of passing HP certification HP0-P19 exam, so the results of their research can 100% guarantee you HP certification HP0-P19 exam for one time. IT-Tests's training tools are very effective and many people who have passed a number of IT certification exams used the practice questions and answers provided by IT-Tests. Some of them who have passed the HP certification HP0-P19 exam also use IT-Tests's products. Selecting IT-Tests.com means choosing a success
Are you still worrying about how to safely pass HP certification HP0-P19 exams? Do you have thought to select a specific training? Choosing a good training can effectively help you quickly consolidate a lot of IT knowledge, so you can be well ready for HP certification HP0-P19 exam. IT-Tests's expert team used their experience and knowledge unremitting efforts to do research of the previous years exam, and finally have developed the best pertinence training program about HP certification HP0-P19 exam. Our training program can effectively help you have a good preparation for HP certification HP0-P19 exam. IT-Tests's training program will be your best choice.
Exam Code: HP0-P19
Exam Name: HP (HP-UX High Availability Using Serviceguard v18)
If you are still struggling to prepare for passing HP0-P19 certification exam, at this moment IT-Tests.com can help you solve problem. IT-Tests.com can provide you training materials with good quality to help you pass the exam, then you will become a good HP HP0-P19 certification member. If you have decided to upgrade yourself by passing HP certification HP0-P19 exam, then choosing IT-Tests.com is not wrong. Our IT-Tests.com promise you that you can pass your first time to participate in the HP certification HP0-P19 exam and get HP HP0-P19 certification to enhance and change yourself.
How far the distance between words and deeds? It depends to every person. If a person is strong-willed, it is close at hand. I think you should be such a person. Since to choose to participate in the HP HP0-P19 certification exam, of course, it is necessary to have to go through. This is also the performance that you are strong-willed. IT-Tests.com HP HP0-P19 exam training materials is the best choice to help you pass the exam. The training materials of IT-Tests.com website have a unique good quality on the internet. If you want to pass the HP HP0-P19 exam, you'd better to buy IT-Tests.com's exam training materials quickly.
HP0-P19 (HP-UX High Availability Using Serviceguard v18) Free Demo Download: http://www.it-tests.com/HP0-P19.html
NO.1 Your customer wants you to design an HA solution with HP-UX and Serviceguard that runs the
customer's Business Critical SAP production system as Serviceguard package, pkgA, and the customer's
Development SAP system as Serviceguard package, pkgB.
You design two vPars (vpar1 and vpar2) on serverA and two vPars (vpar3 and vpar4) on serverB.
What is a good design for this cluster to provide the maximum high availability? (Select two.)
A. Cluster vpar1 and vpar2 and run pkgA on these clustered vPars.
B. Cluster vpar1 and vpar3 and run pkgA on these clustered vPars.
C. Cluster vpar2 and vpar4 and run pkgB on these clustered vPars.
D. Cluster vpar3 and vpar4 and run pkgB on these clustered vPars.
Answer: BC
HP HP0-P19 HP0-P19 test questions HP0-P19 certification training
NO.2 What does OL* (OnLine Replacement, Addition, and Deletion) provide?
A. online replacement, addtion, and deletion of vPARs
B. online replacement, addition, and deletion of PCI(-X) I/O cards
C. online replacement, addition, and deletion of cell boards in cell based systems
D. online replacement, addition, and deletion of PCI(-X) I/O cards and core I/O cards
Answer: B
HP HP0-P19 exam dumps HP0-P19 test answers HP0-P19 HP0-P19
NO.3 Which application templates are included in the Enterprise Cluster Master Toolkit (ECMT)? (Select
four.)
A. NFS
B. SAP
C. SAPDB
D. HP Tomcat
E. HP Apache
F. HP CIFS/9000
G. Oracle 9i and 10g
Answer: DEFG
HP HP0-P19 HP0-P19 exam HP0-P19
NO.4 What is the function of the lock disk or Quorum server in a Serviceguard cluster?
A. prevents split brain syndrome
B. determines which node becomes the cluster coordinator
C. ensures that quorum is present the entire time the cluster is up
D. keeps a record of volume groups that are locked in exclusive mode
Answer: A
HP HP0-P19 answers real questions HP0-P19 HP0-P19 exam dumps HP0-P19 exam simulations
NO.5 Which statements are true regarding High Availability (HA)? (Select three.)
A. Downtime is any amount of time when the application is unavailable (planned or unplanned).
B. HA systems provide a disaster tolerant solution that allows recovery from the loss of an entire data
center.
C. Unplanned downtime is be caused by a failure of a non-redundant hardware component on a cluster
node.
D. Metrocluster and Extended Campus Cluster solutions provide the same level of protection as a local
HA solution in case of environmental disasters.
E. HA is a combination of environmental, process, software, and computing hardware enhancements that
maximize the time that the application and system are available.
F. Highly available systems typically contain data redundancy through mirroring or RAID, some kind of
backup system hardware, power outage protection, and multiple LANs.
Answer: AEF
HP exam HP0-P19 HP0-P19 HP0-P19 HP0-P19
NO.6 You are asked by your management team to do a presentation and explain why your IT department
should go with the SGeRAC solution instead of the standard single-instance Oracle implementation with
Serviceguard.
Which benefits should you present? (Select two.)
A. reduces the overall cost
B. increases the security level
C. provides easier cluster management
D. reduces recovery time of a large database
E. provides the ability to add more nodes to the cluster on the fly
F. increases processing power without the need to administer separate databases
Answer: DF
HP exam simulations HP0-P19 HP0-P19 demo HP0-P19 HP0-P19
NO.7 Which components are considered potential single points of failure within a single HP-UX server?
(Select four.)
A. SAN
B. memory
C. backplane
D. DVD drive
E. LAN interfaces
F. mirrored root disks
G. system adminstrator
H. redundant power supply
I. Fibre Channel Host Bus Adapter
Answer: BCEI
HP exam prep HP0-P19 HP0-P19 HP0-P19 practice test HP0-P19 questions HP0-P19 original questions
NO.8 What are advantages of RAC cluster? (Select three.)
A. increases user scalability
B. increases database security
C. supports larger database size
D. increases hardware scalability
E. increases database availability
F. increases application scalability
G. decreases package failover time
Answer: DEF
HP dumps HP0-P19 HP0-P19 dumps HP0-P19 test questions
NO.9 A customer has a 2-node HP Serviceguard cluster running a mission critical Oracle database and a
financial application. At the end of each month the server utilization spikes with no idle CPU resources
and there is a need for additional capacity.
Which HP Virtual Server Environment offering provides additional capacity and is best in this situation?
A. Capacity Advisor
B. Instant Capacity (iCAP)
C. Integrity Virtual Machines
D. Global Workload Manager (gWLM)
E. Temporary Instant Capacity (TiCAP)
Answer: E
HP study guide HP0-P19 test questions HP0-P19 HP0-P19 test HP0-P19 exam dumps
NO.10 Which configurations are valid for a Serviceguard environment in combination with Integrity Virtual
machines? (Select two.)
A. Configuration 1
B. Configuration 2
C. Configuration 3
D. Configuration 4
Answer: AB
HP HP0-P19 HP0-P19
NO.11 In a Serviceguard implementation for concurrent instances of an Oracle RAC Database, which type of
shared storage management can be used on all nodes in the cluster? (Select three.)
A. Cluster File System (CFS)
B. Veritas Volume Manager (VxVM)
C. Network Attached Storage (NAS)
D. Shared Logical Volume Manager (SLVM)
E. Standard Logical Volume Manager (LVM)
F. Enterprise Logical Volume Manager (ELVM)
G. Oracle Automatic Storage Management (ASM)
Answer: ADG
HP HP0-P19 HP0-P19 HP0-P19 exam prep
NO.12 When a Serviceguard package fails over in a highly available vPar environment, Workload Manager
(WLM) integrates with Serviceguard and disaster tolerant solutions by doing which process?
A. WLM creates a new vPar to assume the load of the failed partition.
B. cmcld creates a new vPar to assume the load of the failed partition.
C. WLM moves processor resources from one virtual partition to another.
D. cmcld moves processor resources from one virtual partition to another.
E. WLM can move a Serviceguard package from one virtual partition to another.
Answer: C
HP practice test HP0-P19 HP0-P19
NO.13 Which products offer a solution to protect from failure of a complete data center? (Select three.)
A. Metrocluster
B. Serviceguard
C. Continentalclusters
D. Extended Campus Cluster
E. Enterprise Cluster Master Toolkit
Answer: ACD
HP HP0-P19 test questions HP0-P19 HP0-P19 pdf HP0-P19 pdf
NO.14 What are the advantages with respect to application availability for a customer using Serviceguard in
an HA environment? (Select two.)
A. Application database corruptions will be minimized.
B. An upgrade of the operating system will only require a package switch.
C. A power outage in the customer's computer room will not affect the users.
D. Rolling upgrades of the application can be performed in a Serviceguard environment.
E. A failure in a redundant power supply will only cause a package switch to the adoptive node.
Answer: BD
HP certification HP0-P19 exam dumps HP0-P19 HP0-P19 demo HP0-P19 original questions
NO.15 What is the purpose of the cluster interconnect in a Serviceguard extension for Oracle RAC
implementation? (Select two.)
A. Nodes can use it for cluster heartbeat traffic.
B. Nodes coordinate the shared storage status.
C. Oracle single instances coordinate their online/offline status.
D. Oracle RAC instances coordinate the consistency between their Oracle buffer cache.
Answer: AD
HP braindump HP0-P19 HP0-P19 exam simulations
NO.16 Which failure scenarios are transparent to application users when the application is running as a
Serviceguard package? (Select two.)
A. A LAN interface fails on a node where no package is running.
B. A complete power outage in the computer room where the cluster is located.
C. A redundant power supply fails in the cluster node running the application package.
D. Manual application package switch because of planned downtime on the cluster node.
E. The cluster node running the application package crashes because of a memory multibit error.
Answer: AC
HP HP0-P19 HP0-P19 HP0-P19 HP0-P19 test
NO.17 Which statement is correct concerning the difference between a local Serviceguard cluster and an
extended distance cluster (also known as a campus cluster)?
A. An extended distance cluster provides disaster tolerance across two data centers located on different
continents.
B. An extended distance cluster solution typically requires a physical data replication mechanism between
high end storage arrays.
C. An extended distance cluster solution typically uses host based disk mirroring between two computer
rooms in an IT environment.
D. An extended distance cluster is a separate product installation to implement High Availability between
two computer rooms in a IT environment.
Answer: C
HP certification training HP0-P19 HP0-P19 HP0-P19
NO.18 In which situations can a local high availability solution prevent unplanned downtime? (Select two.)
A. An operator accidentially reboots a cluster node.
B. The shared storage component looses A/C power and goes down.
C. A complete data center goes down because of an environmental disaster.
D. The network communication between the cluster nodes is permanently interrupted.
E. The clustered application database becomes corrupted by installation of an application patch.
Answer: AD
HP HP0-P19 test answers HP0-P19 HP0-P19 test
NO.19 Consider the following entry in the /etc/rc.config.d/cmcluster file.
AUTOSTART_CMCLD=1
Which parameter in the cluster ascii file is affected by this entry?
A. CMCLD_TIMEOUT
B. CMCLD_RUN_START
C. AUTOSTART_CMCLD
D. AUTOSTART_TIMEOUT
E. HEARTBEAT_INTERVAL
Answer: D
HP braindump HP0-P19 HP0-P19 pdf HP0-P19 answers real questions
NO.20 In the context of high availability, which statements are true regarding split-brain syndrome? (Select
two.)
A. It can occur on a 2-node cluster.
B. It can occur on a 3-node cluster.
C. It allows different applications to simulatneously access the same disk.
D. It allows different partitions to access the same disk without knowledge of each other.
E. It is caused when two clusters initiate an application that accesses the same disk simultaneously.
F. It is caused when two equal size sub-clusters form from a single cluster without knowledge of each
other.
Answer: AF
HP HP0-P19 HP0-P19 HP0-P19 exam prep HP0-P19 exam dumps HP0-P19
NO.21 When implementing a legacy package utilizing application monitoring, which variable in the package
control script will point to the monitor script?
A. service_cmd
B. SERVICE_CMD
C. MONITOR_CMD
D. MONITOR_NAME
Answer: B
HP test HP0-P19 HP0-P19 certification training HP0-P19 HP0-P19
NO.22 In the context of high availability, which phrase describes Mean Time To Repair (MTTR)?
A. mean interval of time to resume a service after a failure
B. mean time a service engineer needs to repair a failed server
C. mean interval of time when the system provides service without fault
D. mean time a service engineer needs to replace a server after a failure
E. mean time a service engineer needs to arrive at the site of a failed server
Answer: A
HP HP0-P19 HP0-P19 exam simulations HP0-P19
NO.23 Which situations does Serviceguard provide high availability solutions for? (Select two.)
A. LAN card failure
B. application failure
C. client subnet goes down
D. poor application performance
E. failure of one of the LUN paths to shared storage
Answer: AB
HP HP0-P19 pdf HP0-P19
NO.24 An e-ticketing application based on Apache webserver for a busy tourist market experiences failures
during peak season, resulting in loss of revenues.
Which product combination implements a solution that improves availability of the e-ticketing application?
(Select two.)
A. HP Serviceguard
B. Continental Clusters
C. HP Serviceguard Extension for SAP
D. Enterprise Cluster Master Toolkit
E. HP Serviceguard Extension for RAC
Answer: AD
HP HP0-P19 pdf HP0-P19 HP0-P19
NO.25 Which statements are true regarding Serviceguard Manager version 5.01? (Select three.)
A. Serviceguard Manager is a graphical user interface for the Serviceguard product.
B. With Serviceguard Manager you can monitor, administer, and configure clusters managed by
Serviceguard.
C. With Serviceguard Manager you can run a multinode cluster which consists of both HP-UX and Linux
nodes.
D. With Serviceguard Manager you can change package-switching and node-switching flags for failover
packages.
E. With Serviceguard Manager you can install Serviceguard software product on hosts managed by HP
Systems Insight Manager (HP SIM).
Answer: ABD
HP HP0-P19 HP0-P19 exam dumps HP0-P19 exam prep HP0-P19 HP0-P19
NO.26 In the context of high availability, which phrase describes Mean Time Between Failure (MTBF)?
A. mean time to restart a failed service
B. mean time to repair a server after a failure
C. mean time to restart a server after a failure
D. mean time a system provides service without failure
Answer: D
HP dumps HP0-P19 certification HP0-P19 HP0-P19 exam prep HP0-P19 exam prep
NO.27 What are the main features of OL* (OnLine Replacement, Addition, and Deletion)? (Select two.)
A. ability to replace a cell board on an HP-UX system that supports OL*
B. ability to repair a PCI I/O card on an HP-UX system that supports OL*
C. ability to online replace a PCI I/O card on an HP-UX system that supports OL*
D. ability to online remove a PCI(-X) card on an HP-UX system that supports OL*
E. ability to online replace an HP-UX system that supports OL* while it is configured in a Serviceguard
cluster
F. ability to online remove a PCI(-X) LAN card and afterwards to online add a PCI(-X) FC HBA in the same
PCI(-X) slot on an HP-UX system that supports OL*
Answer: CD
HP test answers HP0-P19 HP0-P19 questions HP0-P19 questions HP0-P19 HP0-P19
NO.28 Click the Exhibit button.
Based on the cmviewcl output, which statement is correct?
A. A failure of ora_lsnr will cause alien_pkg to failover.
B. A single failure of oracle9i will cause alien_pkg to failover.
C. The subnet 192.168.1.0 going down will cause alien_pkg to failover.
D. A failure of either ora_lsnr or oracle9i will cause alien_pkg to failover.
Answer: C
HP HP0-P19 HP0-P19
NO.29 What are potential single points of failure (SPOF) in an HP-UX system? (Select four.)
A. hard disk drive
B. operating system
C. system administrator
D. redundant power supply
E. CPU on a Uniprocessor system
F. multi-port network interface card
G. alternate link to a disk in a shared volume group
Answer: ABEF
HP HP0-P19 HP0-P19 braindump HP0-P19 HP0-P19 study guide HP0-P19 demo
NO.30 What are potential single points of failure (SPOF) in an HP-UX environment? (Select two.)
A. backplane of a cell based server when two vPARs are clustered with Serviceguard over two physical
nodes
B. backplane of a cell based server when two vPARs are clustered with Serviceguard on the same
physical node
C. cellboard on a partioned node with two nPARs that are clustered with Serviceguard on the same
physical node
D. cellboard on a single-nPar node with two vPARs that are clustered with Serviceguard on the same
physical node
Answer: BD
HP HP0-P19 test questions HP0-P19 HP0-P19
In this competitive society, being good at something is able to take up a large advantage, especially in the IT industry. Gaining some IT authentication certificate is very useful. HP HP0-P19 is a certification exam to test the IT professional knowledge level and has a Pivotal position in the IT industry. While HP HP0-P19 exam is very difficult to pass, so in order to pass the HP certification HP0-P19 exam a lot of people spend a lot of time and effort to learn the related knowledge, but in the end most of them do not succeed. Therefore IT-Tests.com is to analyze the reasons for their failure. The conclusion is that they do not take a pertinent training course. Now IT-Tests.com experts have developed a pertinent training program for HP certification HP0-P19 exam, which can help you spend a small amount of time and money and 100% pass the exam at the same time.
没有评论: